Vulnerabilities

CVE-2026-50577

High 7.4 CVSS 3.1

Description

ePA 3.x Integration implements the authorization workflow and writes Medical Information Objects to Germany's electronic patient record. Prior to 1.3.0, ePA 3.x Integration leaves request_counter unchanged in app/vau/VAUProtokoll.py while constructing VAU messages. The frozen client request counter causes the server side to reuse AES-GCM nonce and key combinations across responses. A network attacker who collects repeated ciphertexts can recover the XOR of plaintexts and use predictable inner HTTP headers and JSON fields to recover sensitive data, including patient health records. Repeated nonces can also enable recovery of the GHASH authentication key through the Joux forbidden attack, allowing forged AES-GCM messages and injection of malicious responses. The response-counter check also fails to maintain last_response_counter, weakening replay and ordering validation. This issue is fixed in version 1.3.0.

Description as published by the source, in English.

Key facts

Published
2026-08-18
Last modified
2026-10-22
Assigned by
security-advisories@github.com
CVSS vector
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N
Scored by
security-advisories@github.com
Fix available
Not registered in the sources

Weakness type

References

Does this affect you?

A vulnerability matters only if you run the product, in an affected version, somewhere an attacker can reach.