CVE-2026-22323
Description
A CSRF vulnerability in the Link Aggregation configuration interface allows an unauthenticated remote attacker to trick authenticated users into sending unauthorized POST requests to the device by luring them to a malicious webpage. This can silently alter the device’s configuration without the victim’s knowledge or consent. Availability impact was set to low because after a successful attack the device will automatically recover without external intervention.
Description as published by the source, in English.
Key facts
- Published
- 2026-03-18
- Last modified
- 2026-06-17
- Assigned by
- info@cert.vde.com
- CVSS vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:L- Scored by
- info@cert.vde.com
- Probability of exploitation
-
0.2 %
higher than 8 %
of all known vulnerabilities
EPSS, next 30 days, model v2026.06.15 - Fix available
- Not registered in the sources
Affected products
| Vendor | Product | Versions | Status |
|---|---|---|---|
| Phoenix Contact | FL NAT 2008 | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL NAT 2208 | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL NAT 2304-2GC-2SFP | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2005 | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2008 | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2008F | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2016 | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2105 | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2108 | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2116 | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2204-2TC-2SFX | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2205 | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2206-2FX | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2206-2FX SM | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2206-2FX SM ST | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2206-2FX ST | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2206-2SFX | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2206-2SFX PN | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2206C-2FX | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2207-FX | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2207-FX SM | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2208 | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2208 PN | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2208C | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2212-2TC-2SFX | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2214-2FX | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2214-2FX SM | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2214-2SFX | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2214-2SFX PN | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2216 | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2216 PN | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2303-8SP1 | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2304-2GC-2SFP | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2306-2SFP | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2306-2SFP PN | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2308 | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2308 PN | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2312-2GC-2SFP | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2314-2SFP | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2314-2SFP PN | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2316 | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2316/K1 | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2316 PN | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2404-2TC-2SFX | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2406-2SFX | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2406-2SFX PN | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2408 | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2408 PN | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2412-2TC-2SFX | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2414-2SFX | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2414-2SFX PN | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2416 | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2416 PN | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2504-2GC-2SFP | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2506-2SFP | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2506-2SFP/K1 | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2506-2SFP PN | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2508 | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2508/K1 | ≥ 0.0.0, < 3.53 | Affected |
| Phoenix Contact | FL SWITCH 2508 PN | ≥ 0.0.0, < 3.53 | Affected |
Weakness type
-
CWE-352: Cross-Site Request Forgery
The web application does not, or cannot, sufficiently verify whether a request was intentionally provided by the user who sent the request, which could have originated from an unauthorized actor.
References
Does this affect you?
A vulnerability matters only if you run the product, in an affected version, somewhere an attacker can reach.