CVE-2026-13380
Description
VSee Clinic 7.1.26 and VSee Clinic API 1.3.0 exposes cleartext SFTP credentials in the HTTP responses of three unauthenticated endpoints. The credentials are present in these responses only when SFTP connections have been configured within the application. No authentication is required to retrieve these credentials. An unauthenticated remote attacker who observes any of these HTTP responses on an instance where SFTP is configured can obtain the credentials and use them to access the associated SFTP server.
Description as published by the source, in English.
Key facts
- Published
- 2026-07-20
- Last modified
- 2026-10-24
- Assigned by
- 57dba5dd-1a03-47f6-8b36-e84e47d335d8
- CVSS vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N- Scored by
- nvd@nist.gov (NVD Primary)
- Probability of exploitation
-
0.3 %
higher than 18 %
of all known vulnerabilities
EPSS, next 30 days, model v2026.06.15 - Fix available
- Not registered in the sources
Affected products
| Vendor | Product | Versions | Status |
|---|---|---|---|
| Vsee | Clinic | 7.1.26 | Affected |
| Vsee | Clinic Api | 1.3.0 | Affected |
Weakness type
-
CWE-201: Insertion of Sensitive Information Into Sent Data
The code transmits data to another actor, but a portion of the data includes sensitive information that should not be accessible to that actor.
-
CWE-312: Cleartext Storage of Sensitive Information
The product stores sensitive information in cleartext within a resource that might be accessible to another control sphere.
Attack techniques
Derived through the weakness type: CVE to CWE to CAPEC to ATT&CK. This shows which techniques the weakness class is historically used for. It does not assert that this vulnerability has been exploited that way.
- T1005: Data from Local System
- T1552.004: Private Keys
References
Related at Berigo
Articles
-
Malware knocked out phones and internet at the AnMed health system
Same product
2026-08-18
A malware attack knocked out the phone and internet systems at the US health system AnMed. Offices and imaging services were closed, and elective pro…
-
Shared Claude conversations turned up in Google search
Same product
2026-08-18
On 27 July 2026 404 Media reported that shared Claude conversations and artifacts appeared in Google search results. The findings included medical re…
-
Cisco Talos shows how DICOM files can be used against imaging systems
Same product
2026-05-28
A Cisco Talos white paper demonstrates how an Orthanc server can be targeted during image upload, resulting in an out-of-bounds write.
Does this affect you?
A vulnerability matters only if you run the product, in an affected version, somewhere an attacker can reach.