Vulnerabilities

CVE-2026-124761

High 7.1 CVSS 4.0

Description

P-Net before 1.0.4 copies the IP suite of a DCP Set request to the current and the non-volatile configuration, and starts saving it, before the state of the device is checked. If the request is refused, for example because an Application Relationship is active, the configuration is not restored and is still saved. After a restart the device uses the refused address, and may not answer the controller or may use its address. A host with ADJACENT network access can use this while an Application Relationship is active.

Description as published by the source, in English.

Key facts

Published
2026-11-13
Last modified
2026-11-17
Assigned by
4b71179a-3b92-4a9d-b9fc-af8b8ed579ee
CVSS vector
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:
Scored by
4b71179a-3b92-4a9d-b9fc-af8b8ed579ee
Fix available
Not registered in the sources

Weakness type

  • CWE-696: Incorrect Behavior Order

    The product performs multiple related behaviors, but the behaviors are performed in the wrong order in ways that may produce resultant weaknesses.