A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All versions < V3.2), SCALANCE XCM324 (6GK5324-8TS01-2AC2) (All versions < V3.2), SCALANCE XCM328 (6GK5328-4TS01-2AC2) (All versions < V3.2), SCALANCE XCM332 (6GK5332-0GA01-2AC2) (All versions < V3.2), SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3) (All versions < V3.2). The "Load Configuration from Local PC" functionality in the web interface of affected products contains a race condition vulnerability. This could allow an authenticated remote attacker to make the affected product load an attacker controlled configuration instead of the legitimate one. Successful exploitation requires that a legitimate administrator invokes the functionality and the attacker wins the race condition.

Description as published by the source, in English.

Key facts

Published
2025-06-10
Last modified
2026-06-17
Assigned by
productcert@siemens.com
CVSS vector
CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:P/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:
Scored by
productcert@siemens.com
Probability of exploitation
0.2 % higher than 16 % of all known vulnerabilities
EPSS, next 30 days, model v2026.06.15
Fix available
Not registered in the sources

Affected products

Vendor Product Versions Status
Siemens RUGGEDCOM RST2428P ≥ 0, < V3.2 Affected
Siemens SCALANCE XCH328 ≥ 0, < V3.2 Affected
Siemens SCALANCE XCM324 ≥ 0, < V3.2 Affected
Siemens SCALANCE XCM328 ≥ 0, < V3.2 Affected
Siemens SCALANCE XCM332 ≥ 0, < V3.2 Affected
Siemens SCALANCE XRH334 (24 V DC, 8xFO, CC) ≥ 0, < V3.2 Affected
Siemens SCALANCE XRM334 (230 V AC, 12xFO) ≥ 0, < V3.2 Affected
Siemens SCALANCE XRM334 (230 V AC, 8xFO) ≥ 0, < V3.2 Affected
Siemens SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) ≥ 0, < V3.2 Affected
Siemens SCALANCE XRM334 (24 V DC, 12xFO) ≥ 0, < V3.2 Affected
Siemens SCALANCE XRM334 (24 V DC, 8xFO) ≥ 0, < V3.2 Affected
Siemens SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) ≥ 0, < V3.2 Affected
Siemens SCALANCE XRM334 (2x230 V AC, 12xFO) ≥ 0, < V3.2 Affected
Siemens SCALANCE XRM334 (2x230 V AC, 8xFO) ≥ 0, < V3.2 Affected
Siemens SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) ≥ 0, < V3.2 Affected

Weakness type

References

Does this affect you?

A vulnerability matters only if you run the product, in an affected version, somewhere an attacker can reach.