CVE-2022-27779
Description
libcurl wrongly allows cookies to be set for Top Level Domains (TLDs) if thehost name is provided with a trailing dot.curl can be told to receive and send cookies. curl's "cookie engine" can bebuilt with or without [Public Suffix List](https://publicsuffix.org/)awareness. If PSL support not provided, a more rudimentary check exists to atleast prevent cookies from being set on TLDs. This check was broken if thehost name in the URL uses a trailing dot.This can allow arbitrary sites to set cookies that then would get sent to adifferent and unrelated site or domain.
Description as published by the source, in English.
Key facts
- Published
- 2022-06-02
- Last modified
- 2026-11-02
- Assigned by
- support@hackerone.com
- CVSS vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N- Scored by
- nvd@nist.gov (NVD Primary)
- Probability of exploitation
-
2.6 %
higher than 84 %
of all known vulnerabilities
EPSS, next 30 days, model v2026.06.15 - Fix available
- Not registered in the sources
Affected products
| Vendor | Product | Versions | Status |
|---|---|---|---|
| Haxx | Curl | ≥ 7.82.0, < 7.83.1 | Affected |
| Netapp | Clustered Data Ontap | all versions listed | Affected |
| Netapp | H300s | all versions listed | Not affected |
| Netapp | H300s Firmware | all versions listed | Affected |
| Netapp | H410s | all versions listed | Not affected |
| Netapp | H410s Firmware | all versions listed | Affected |
| Netapp | H500s | all versions listed | Not affected |
| Netapp | H500s Firmware | all versions listed | Affected |
| Netapp | H700s | all versions listed | Not affected |
| Netapp | H700s Firmware | all versions listed | Affected |
| Netapp | Hci Bootstrap Os | all versions listed | Affected |
| Netapp | Hci Compute Node | all versions listed | Not affected |
| Netapp | Hci Compute Node | all versions listed | Affected |
| Netapp | Solidfire & Hci Management Node | all versions listed | Affected |
| Netapp | Solidfire, Enterprise Sds & Hci Storage Node | all versions listed | Affected |
| Splunk | Universal Forwarder | 9.1.0 | Affected |
| Splunk | Universal Forwarder | ≥ 8.2.0, < 8.2.12 | Affected |
| Splunk | Universal Forwarder | ≥ 9.0.0, < 9.0.6 | Affected |
Weakness type
-
CWE-201: Insertion of Sensitive Information Into Sent Data
The code transmits data to another actor, but a portion of the data includes sensitive information that should not be accessible to that actor.
References
- https://hackerone.com/reports/1553301
- https://security.gentoo.org/glsa/202212-01
- https://security.netapp.com/advisory/ntap-20220609-0009/
- https://hackerone.com/reports/1553301
- https://security.gentoo.org/glsa/202212-01
- https://security.netapp.com/advisory/ntap-20220609-0009/
- https://cert-portal.siemens.com/productcert/html/ssa-398330.html
Does this affect you?
A vulnerability matters only if you run the product, in an affected version, somewhere an attacker can reach.