A security vulnerability has been detected in BioStar Temperature Monitor Utility 1.2.1806.2200. Affected by this vulnerability is the function sub_1105C of the file BS_HWMIO64_W10.sys of the component IOCTL Handler. Such manipulation of the argument PhysicalAddress leads to write-what-where condition. The attack needs to be performed locally. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Beskrivelsen gjengis slik kilden har publisert den, på engelsk.

Nøkkelfakta

Publisert
2026-09-21
Sist endret
2026-09-21
Tildelt av
cna@vuldb.com
CVSS-vektor
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:
Scoret av
cna@vuldb.com
Rettelse finnes
Ikke registrert hos kildene

Svakhetstype

Referanser

Berører dette dere?

En sårbarhet betyr bare noe hvis dere kjører produktet, i en berørt versjon, et sted en angriper kommer til.

Sjekk aktivalisten deres Bla i alle sårbarheter