Sårbarheter

CVE-2026-50577

Høy 7.4 CVSS 3.1

Beskrivelse

ePA 3.x Integration implements the authorization workflow and writes Medical Information Objects to Germany's electronic patient record. Prior to 1.3.0, ePA 3.x Integration leaves request_counter unchanged in app/vau/VAUProtokoll.py while constructing VAU messages. The frozen client request counter causes the server side to reuse AES-GCM nonce and key combinations across responses. A network attacker who collects repeated ciphertexts can recover the XOR of plaintexts and use predictable inner HTTP headers and JSON fields to recover sensitive data, including patient health records. Repeated nonces can also enable recovery of the GHASH authentication key through the Joux forbidden attack, allowing forged AES-GCM messages and injection of malicious responses. The response-counter check also fails to maintain last_response_counter, weakening replay and ordering validation. This issue is fixed in version 1.3.0.

Beskrivelsen gjengis slik kilden har publisert den, på engelsk.

Nøkkelfakta

Publisert
2026-08-18
Sist endret
2026-10-22
Tildelt av
security-advisories@github.com
CVSS-vektor
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N
Scoret av
security-advisories@github.com
Rettelse finnes
Ikke registrert hos kildene

Svakhetstype

Referanser

Berører dette dere?

En sårbarhet betyr bare noe hvis dere kjører produktet, i en berørt versjon, et sted en angriper kommer til.

Sjekk aktivalisten deres Bla i alle sårbarheter