CVE-2026-17091
Beskrivelse
IBM PowerVM Hypervisor FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the PowerVM hypervisor call interface. An attacker with root access to a guest partition can issue a specially crafted hypervisor call to inject an arbitrary amount of data into hypervisor or partition memory, resulting in either a crash causing a full platform re-IPL and terminating all hosted partitions, or corruption of hypervisor or partition memory. The PowerVM hypervisor will restart automatically; however, repeated exploitation could result in a sustained availability impact. Successful exploitation results in an integrity and availability impact to the managed system.
Beskrivelsen gjengis slik kilden har publisert den, på engelsk.
Nøkkelfakta
- Publisert
- 2026-08-19
- Sist endret
- 2026-08-25
- Tildelt av
- psirt@us.ibm.com
- CVSS-vektor
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:H/A:H- Scoret av
- psirt@us.ibm.com
- Rettelse finnes
- Ikke registrert hos kildene
Berørte produkter
| Leverandør | Produkt | Versjoner | Status |
|---|---|---|---|
| Ibm | Power System E1050 (9043-mrx) | alle oppførte versjoner | Ikke berørt |
| Ibm | Power System E1050 (9043-mrx) Firmware | ≥ fw1060.00, < fw1060.81 | Berørt |
| Ibm | Power System E1080 (9080-hex) | alle oppførte versjoner | Ikke berørt |
| Ibm | Power System E1080 (9080-hex) Firmware | ≥ fw1060.00, < fw1060.81 | Berørt |
| Ibm | Power System E1150 (9043-mru) | alle oppførte versjoner | Ikke berørt |
| Ibm | Power System E1150 (9043-mru) Firmware | fw1120.00 | Berørt |
| Ibm | Power System E1150 (9043-mru) Firmware | ≥ fw1110.00, < fw1110.31 | Berørt |
| Ibm | Power System E1180 (9080-heu) | alle oppførte versjoner | Ikke berørt |
| Ibm | Power System E1180 (9080-heu) Firmware | fw1120.00 | Berørt |
| Ibm | Power System E1180 (9080-heu) Firmware | ≥ fw1110.00, < fw1110.31 | Berørt |
| Ibm | Power System E950 (9040-mr9) | alle oppførte versjoner | Ikke berørt |
| Ibm | Power System E950 (9040-mr9) Firmware | ≥ fw950.00, < fw950.h3 | Berørt |
| Ibm | Power System E980 (9080-m9s) | alle oppførte versjoner | Ikke berørt |
| Ibm | Power System E980 (9080-m9s) Firmware | ≥ fw950.00, < fw950.h3 | Berørt |
| Ibm | Power System H922 (9223-22s) | alle oppførte versjoner | Ikke berørt |
| Ibm | Power System H922 (9223-22s) Firmware | ≥ fw950.00, < fw950.h3 | Berørt |
| Ibm | Power System H924 (9223-42s) | alle oppførte versjoner | Ikke berørt |
| Ibm | Power System H924 (9223-42s) Firmware | ≥ fw950.00, < fw950.h3 | Berørt |
| Ibm | Power System L1022 (9786-22h) | alle oppførte versjoner | Ikke berørt |
| Ibm | Power System L1022 (9786-22h) Firmware | ≥ fw1060.00, < fw1060.81 | Berørt |
| Ibm | Power System L1024 (9786-42h) | alle oppførte versjoner | Ikke berørt |
| Ibm | Power System L1024 (9786-42h) Firmware | ≥ fw1060.00, < fw1060.81 | Berørt |
| Ibm | Power System L1122 (9856-22h) | alle oppførte versjoner | Ikke berørt |
| Ibm | Power System L1122 (9856-22h) Firmware | fw1120.00 | Berørt |
| Ibm | Power System L1122 (9856-22h) Firmware | ≥ fw1110.00, < fw1110.31 | Berørt |
| Ibm | Power System L1124 (9856-42h) | alle oppførte versjoner | Ikke berørt |
| Ibm | Power System L1124 (9856-42h) Firmware | fw1120.00 | Berørt |
| Ibm | Power System L1124 (9856-42h) Firmware | ≥ fw1110.00, < fw1110.31 | Berørt |
| Ibm | Power System S1012 (9028-21b) | alle oppførte versjoner | Ikke berørt |
| Ibm | Power System S1012 (9028-21b) Firmware | ≥ fw1060.00, < fw1060.81 | Berørt |
| Ibm | Power System S1014 (9105-41b) | alle oppførte versjoner | Ikke berørt |
| Ibm | Power System S1014 (9105-41b) Firmware | ≥ fw1060.00, < fw1060.81 | Berørt |
| Ibm | Power System S1022 (9105-22a) | alle oppførte versjoner | Ikke berørt |
| Ibm | Power System S1022 (9105-22a) Firmware | ≥ fw1060.00, < fw1060.81 | Berørt |
| Ibm | Power System S1022s (9105-22b) | alle oppførte versjoner | Ikke berørt |
| Ibm | Power System S1022s (9105-22b) Firmware | ≥ fw1060.00, < fw1060.81 | Berørt |
| Ibm | Power System S1024 (9105-42a) | alle oppførte versjoner | Ikke berørt |
| Ibm | Power System S1024 (9105-42a) Firmware | ≥ fw1060.00, < fw1060.81 | Berørt |
| Ibm | Power System S1112 (9242-21b) | alle oppførte versjoner | Ikke berørt |
| Ibm | Power System S1112 (9242-21b) Firmware | fw1120.00 | Berørt |
| Ibm | Power System S1112 (9242-21t) | alle oppførte versjoner | Ikke berørt |
| Ibm | Power System S1112 (9242-21t) Firmware | fw1120.00 | Berørt |
| Ibm | Power System S1114 (9824-41b) | alle oppførte versjoner | Ikke berørt |
| Ibm | Power System S1114 (9824-41b) Firmware | fw1120.00 | Berørt |
| Ibm | Power System S1114 (9824-41b) Firmware | ≥ fw1110.00, < fw1110.31 | Berørt |
| Ibm | Power System S1122 (9824-22a) | alle oppførte versjoner | Ikke berørt |
| Ibm | Power System S1122 (9824-22a) Firmware | fw1120.00 | Berørt |
| Ibm | Power System S1122 (9824-22a) Firmware | ≥ fw1110.00, < fw1110.31 | Berørt |
| Ibm | Power System S1122s (9824-22b) | alle oppførte versjoner | Ikke berørt |
| Ibm | Power System S1122s (9824-22b) Firmware | fw1120.00 | Berørt |
| Ibm | Power System S1122s (9824-22b) Firmware | ≥ fw1110.00, < fw1110.31 | Berørt |
| Ibm | Power System S1124 (9824-42a) | alle oppførte versjoner | Ikke berørt |
| Ibm | Power System S1124 (9824-42a) Firmware | fw1120.00 | Berørt |
| Ibm | Power System S1124 (9824-42a) Firmware | ≥ fw1110.00, < fw1110.31 | Berørt |
| Ibm | Power System S914 (9009-41g) | alle oppførte versjoner | Ikke berørt |
| Ibm | Power System S914 (9009-41g) Firmware | ≥ fw950.00, < fw950.h3 | Berørt |
| Ibm | Power System S922 (9009-22g) | alle oppførte versjoner | Ikke berørt |
| Ibm | Power System S922 (9009-22g) Firmware | ≥ fw950.00, < fw950.h3 | Berørt |
| Ibm | Power System S924 (9009-42g) | alle oppførte versjoner | Ikke berørt |
| Ibm | Power System S924 (9009-42g) Firmware | ≥ fw950.00, < fw950.h3 | Berørt |
Svakhetstype
-
CWE-190: Integer Overflow or Wraparound
The product performs a calculation that can produce an integer overflow or wraparound when the logic assumes that the resulting value will always be larger than the original value. This occurs when an integer value is i…
Referanser
Berører dette dere?
En sårbarhet betyr bare noe hvis dere kjører produktet, i en berørt versjon, et sted en angriper kommer til.