Sårbarheter

CVE-2023-29054

Høy 7.4 CVSS 3.1

Beskrivelse

A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT PRO (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2P IRT (All versions < V5.5.2), SCALANCE X202-2P IRT PRO (All versions < V5.5.2), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT PRO (All versions < V5.5.2), SCALANCE XF201-3P IRT (All versions < V5.5.2), SCALANCE XF202-2P IRT (All versions < V5.5.2), SCALANCE XF204-2BA IRT (All versions < V5.5.2), SCALANCE XF204IRT (All versions < V5.5.2), SIPLUS NET SCALANCE X202-2P IRT (All versions < V5.5.2). The SSH server on affected devices is configured to offer weak ciphers by default. This could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data passed over the connection between legitimate clients and the affected device.

Beskrivelsen gjengis slik kilden har publisert den, på engelsk.

Nøkkelfakta

Publisert
2023-04-11
Sist endret
2026-10-23
Tildelt av
productcert@siemens.com
CVSS-vektor
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N
Scoret av
nvd@nist.gov (NVD Primary)
Sannsynlighet for utnyttelse
0.3 % høyere enn 17 % av alle kjente sårbarheter
EPSS, neste 30 dager, modell v2026.06.15
Rettelse finnes
Ikke registrert hos kildene

Berørte produkter

Leverandør Produkt Versjoner Status
Siemens Scalance X200-4p Irt alle oppførte versjoner Ikke berørt
Siemens Scalance X200-4p Irt Firmware < 5.5.2 Berørt
Siemens Scalance X201-3p Irt alle oppførte versjoner Ikke berørt
Siemens Scalance X201-3p Irt Firmware < 5.5.2 Berørt
Siemens Scalance X201-3p Irt Pro alle oppførte versjoner Ikke berørt
Siemens Scalance X201-3p Irt Pro Firmware < 5.5.2 Berørt
Siemens Scalance X202-2irt alle oppførte versjoner Ikke berørt
Siemens Scalance X202-2irt Firmware < 5.5.2 Berørt
Siemens Scalance X202-2p Irt alle oppførte versjoner Ikke berørt
Siemens Scalance X202-2p Irt Firmware < 5.5.2 Berørt
Siemens Scalance X202-2p Irt Pro alle oppførte versjoner Ikke berørt
Siemens Scalance X202-2p Irt Pro Firmware < 5.5.2 Berørt
Siemens Scalance X204irt alle oppførte versjoner Ikke berørt
Siemens Scalance X204irt Firmware < 5.5.2 Berørt
Siemens Scalance X204irt Pro alle oppførte versjoner Ikke berørt
Siemens Scalance X204irt Pro Firmware < 5.5.2 Berørt
Siemens Scalance Xf201-3p Irt alle oppførte versjoner Ikke berørt
Siemens Scalance Xf201-3p Irt Firmware < 5.5.2 Berørt
Siemens Scalance Xf202-2p Irt alle oppførte versjoner Ikke berørt
Siemens Scalance Xf202-2p Irt Firmware < 5.5.2 Berørt
Siemens Scalance Xf204-2ba Irt alle oppførte versjoner Ikke berørt
Siemens Scalance Xf204-2ba Irt Firmware < 5.5.2 Berørt
Siemens Scalance Xf204irt alle oppførte versjoner Ikke berørt
Siemens Scalance Xf204irt Firmware < 5.5.2 Berørt
Siemens Siplus Net Scalance X202-2p Irt alle oppførte versjoner Ikke berørt
Siemens Siplus Net Scalance X202-2p Irt Firmware < 5.5.2 Berørt

Svakhetstype

  • CWE-326: Inadequate Encryption Strength

    The product stores or transmits sensitive data using an encryption scheme that is theoretically sound, but is not strong enough for the level of protection required.

Angrepsteknikker

Utledet gjennom svakhetstypen: CVE til CWE til CAPEC til ATT&CK. Dette viser hvilke teknikker svakhetsklassen historisk brukes til. Det er ikke en påstand om at nettopp denne sårbarheten er utnyttet slik.

  • T1110: Brute Force credential-access

Referanser

Berører dette dere?

En sårbarhet betyr bare noe hvis dere kjører produktet, i en berørt versjon, et sted en angriper kommer til.

Sjekk aktivalisten deres Bla i alle sårbarheter