Sårbarheter

CVE-2023-2186

Kritisk 9.8 CVSS 3.1

Beskrivelse

On Triangle MicroWorks' SCADA Data Gateway version <= v5.01.03, an unauthenticated attacker can send a specially crafted broadcast message including format string characters to the SCADA Data Gateway to perform unrestricted memory reads.An unauthenticated user can use this format string vulnerability to repeatedly crash the GTWWebMonitor.exe process to DoS the Web Monitor. Furthermore, an authenticated user can leverage this vulnerability to leak memory from the GTWWebMonitor.exe process. This could be leveraged in an exploit chain to gain code execution.

Beskrivelsen gjengis slik kilden har publisert den, på engelsk.

Nøkkelfakta

Publisert
2023-06-07
Sist endret
2026-10-23
Tildelt av
trellixpsirt@trellix.com
CVSS-vektor
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Scoret av
nvd@nist.gov (NVD Primary)
Sannsynlighet for utnyttelse
0.7 % høyere enn 50 % av alle kjente sårbarheter
EPSS, neste 30 dager, modell v2026.06.15
Rettelse finnes
Ikke registrert hos kildene

Berørte produkter

Leverandør Produkt Versjoner Status
Trianglemicroworks Scada Data Gateway ≤ 5.01.03 Berørt

Svakhetstype

Referanser

Berører dette dere?

En sårbarhet betyr bare noe hvis dere kjører produktet, i en berørt versjon, et sted en angriper kommer til.

Sjekk aktivalisten deres Bla i alle sårbarheter